Skip to content
Danfoss

CISA warns of a flaw rated 9.8 out of 10 in Danfoss AK-SM refrigeration controllers

The flaw af­fects ver­sions 5.4.0 and earli­er and can be ex­ploited without a pass­word. Danfoss does not yet have a fix and says the equip­ment should not be ex­posed to the in­ter­net.

By CEO of Lyntev

Published
3 min read

Pale office building with a glazed tower beside a tree-lined road.
Danfoss's main building in Nordborg, Denmark, in May 2008. File photograph. Schnatzel (opens in a new tab). Public domain

Key points

  • On 24 November the US agency CISA published an advisory on CVE-2026-129713 in Danfoss AK-SM 8xxA controllers, rated 9.8 out of 10.
  • The attack runs over the network with no password: it corrupts memory and restarts the web server; code execution is described as hypothetical.
  • Versions 5.4.0 and earlier are affected; a fix is due in version 5.5.x, with no date.
  • Danfoss published the record of the flaw on 20 November and recommends VPN access, Strict Mode and no exposure to the internet.
  • CISA says no public exploitation has been reported to it.

On 24 November the US cy­ber­se­cur­ity agency CISA pub­lished an ad­vis­ory on a crit­ic­al flaw (opens in a new tab) in Danfoss AK-SM 8xxA con­trol­lers, devices that man­age re­fri­ger­a­tion in su­per­mar­kets and ware­houses. The flaw, tracked as CVE-2026-129713, has a sever­ity of 9.8 out of 10, can be ex­ploited without a pass­word and has no fix yet: Danfoss prom­ises one in a fu­ture re­lease. CISA says no pub­lic ex­ploit­a­tion has been re­por­ted to it.

What the advisory says

The prob­lem lies in a pro­gram in the device’s web in­ter­face that ac­cepts re­quests without au­then­tic­a­tion. An at­tack­er who can reach the con­trol­ler over the net­work can send an HTTP or HTTPS re­quest built to trig­ger a stack-based buf­fer over­flow. The ef­fect de­scribed is cor­rup­ted memory and a re­start of the device’s web serv­er.

On code ex­e­cu­tion, the ad­vis­ory uses two word­ings. Its sum­mary says ex­ploit­a­tion “could allow” an at­tack­er to run code with the web serv­er’s priv­ileges. The tech­nic­al de­scrip­tion, writ­ten by Danfoss, is more cau­tious and calls that out­come “hy­po­thet­ic­ally” pos­sible.

Versions 5.4.0 and earli­er of the AK-SM 8xxA series are af­fected. On the CVSS scale, which scores vul­ner­ab­il­it­ies from 0 to 10, sever­ity is 9.8 in ver­sion 3.1 and 9.3 in ver­sion 4.0, both at the crit­ic­al level. The scor­ing vec­tor de­scribes an at­tack over the net­work, of low com­plex­ity, with no priv­ileges and no ac­tion by a user.

The find­ing was re­por­ted to CISA by Carlo Meijer of the com­pany Midnight Blue. CISA says the equip­ment is de­ployed world­wide and that Danfoss is headquartered in Denmark.

What Danfoss has already said

Danfoss it­self pub­lished the re­cord of the flaw (opens in a new tab) in the pub­lic CVE vul­ner­ab­il­ity data­base on 20 November, four days be­fore CISA’s ad­vis­ory. According to the re­cord, the fix will come in soft­ware ver­sion 5.5.x, with no date given. The com­pany will also re­move the op­tion that lets cus­tom­ers switch off “Strict Mode”, the set­ting that, in its words, en­sures high­er se­cur­ity levels.

Until then, the man­u­fac­turer lists four meas­ures:

  • fol­low the manu­al and avoid ex­pos­ing units to the in­ter­net on a pub­lic address;
  • allow re­mote ac­cess only through a se­cure VPN (vir­tu­al private net­work) or a pro­tec­ted network;
  • use Strict Mode;
  • choose strong pass­words.

CISA also re­com­mends pla­cing these sys­tems be­hind fire­walls and sep­ar­at­ing them from the of­fice net­work. It points out that VPNs can have flaws of their own and must be kept up to date. It asks or­gan­isa­tions that no­tice sus­pi­cious activ­ity to re­port it, so that it can be matched with other in­cid­ents.

Why it matters to anyone running cold storage

These con­trol­lers su­per­vise com­pressors, evap­or­at­ors and en­vir­on­ment­al sensors, and keep the re­cords used to prove that the cold chain was main­tained, ac­cord­ing to SecurityBrief (opens in a new tab). In August the pub­lic­a­tion re­por­ted on a study by Claroty, an in­dus­tri­al se­cur­ity firm, into flaws in this equip­ment and in Copeland’s. The risk it de­scribed was of someone tam­per­ing with re­fri­ger­a­tion and spoil­ing food or medi­cines without being no­ticed at once.

Those Danfoss flaws are older and dif­fer­ent from the cur­rent one. CISA cov­ers them in a 2025 ad­vis­ory (opens in a new tab), with CVSS 3.1 scores between 5.4 and 8.2 and fixes in re­leases R4.2 and R4.3.1. Two of the three could be ex­ploited only after log­ging in, and the ad­vis­ory said the at­tack was of high com­plex­ity. The new flaw needs no au­then­tic­a­tion and is of low com­plex­ity. On 18 November CISA re­vised the 2025 ad­vis­ory, but only to up­date links.

Which versions are affected and where they are used

CISA gives no min­im­um ver­sion: it lists every ver­sion up to 5.4.0 as af­fected. Danfoss’s re­cord says the same, start­ing from ver­sion zero. Until 5.5.x is re­leased there is no cor­rec­ted ver­sion to in­stall.

The agency classes the sec­tor as “com­mer­cial fa­cil­it­ies”, and SecurityBrief also men­tions ware­houses, cold-stor­age sites and health­care set­tings among the users of this kind of con­trol­ler. None of the doc­u­ments says how many units there are in each coun­try or how many can be reached from the in­ter­net.

What is still unknown

No date has been given for ver­sion 5.5.x. It is also un­known wheth­er code ex­e­cu­tion, hy­po­thet­ic­al for now, is feas­ible in prac­tice: the pub­lic de­scrip­tion in­cludes no demon­stra­tion. The ad­vis­ory of­fers no way of check­ing wheth­er any­one has already tried to ex­ploit the flaw.

Sources

Documents and reporting consulted for this story.

  1. Danfoss AK-SM 8xxA Series (ICSA-26-328-03) (opens in a new tab)CISA, . Primary source. Accessed 24 November 2026
  2. CVE-2026-129713: Stack-based buffer overflow in Danfoss AK-SM8xxA unauthenticated CGI handler (opens in a new tab)Danfoss (CVE.org), . Primary source. Accessed 24 November 2026
  3. Danfoss AK-SM 8xxA Series, Update A (ICSA-25-140-03) (opens in a new tab)CISA, . Primary source. Accessed 24 November 2026
  4. Refrigeration controller flaws threaten cold chains (opens in a new tab)SecurityBrief Australia, . Accessed 24 November 2026

Editorial principlesReport an error